GrabCAD 模型信息
DIN 42530 Transformer Bushing - 1kV - 3150A (DT1-3150A / DT1-3150B) · 模型 396689
Complete, highly detailed 3D CAD assembly of an outdoor low-voltage heavy-current ceramic transformer bushing equipped with a standardized DIN 43675-FP 4-hole square connecting flag terminal (110x110 mm), designed strictly according to DIN 42530 (EN 50386), DIN 43675, ISO 4032, ISO 4017, and DIN 125 industrial standards. --- ## 🌟 Why Explore This Model? - **Ultra-Heavy-Current Conductor System:** Features the heavy-duty composite copper conductor stem with brass bottom flange (M48x3 thread) and a standardized DIN 43675 4-hole flat palm terminal (c = 110 mm, 60x60 mm center-to-center hole pattern for M12/M16 hardware). - **Dual Assemblies Included:** Both fully assembled configuration AND fully exploded assembly configuration (SolidWorks SLDASM + 14 individual SLDPRT parts). - **Internal Details & Cutaways:** Features anti-rotation locking mechanism, dual internal oil barrier gaskets (X and R), flange gasket (N), and ring gasket (J). - **Industrial Standard Compliance:** Faithfully matches DIN 42530 (Type 1/3150) and DIN 43675-FP standard specifications. --- ## 📸 Visual Showcase Progression: 1. **Assembled 3D View (Isometric):** Full exterior showcase with realistic glazed porcelain finish, heavy M48 conductor, and DIN 43675 4-hole connecting flag. 2. **Cross-Section Cutaway (Isometric):** Detailed interior view revealing internal gasket compression, stem seating, and tank wall mounting. 3. **Exploded Assembly (Isometric):** Complete visual stacking order of all 14 distinct component parts. 4. **2D Engineering Schematic & BOM:** High-resolution dimensioned technical drawing with numbered callouts (Pos 1 to 14) and part list table. 5. **Cross-Section Cutaway (Front):** Orthogonal interior view showing gasket seating and clearances. 6. **Exploded Assembly (Front):** Linear disassembly sequence for assembly manuals and maintenance procedures. 7. **Assembled Front Elevation:** True-scale profile elevation view. 8. **Electrical Ratings & Dimension Matrix:** Official technical datasheet lookup table. --- ### ⚡ Electrical Ratings & Technical Data: - Standard: DIN 42530 (Type 1/3150) - Rated Current (In): 3150 A - Rated Voltage (Un): 1 kV - Maximum Voltage (Um): 1.1 kV - Lightning Impulse Withstand Voltage (1.2 / 50 us): 20 kV - Power Frequency Withstand Voltage (50 Hz, 1 min - Dry & Wet): 10 kV - Creepage Distance: 75 mm --- ### 📏 Dimensions & Mechanical Specifications: - Upper Height above tank plate (a max): 342 mm - Lower Height below tank plate (b m
- 格式
- Parasolid、SOLIDWORKS、STEP / IGES、STL、Rendering
- 分类
- Components、Electrical
- 标签
- transformer、bushing、din42530、din43675、1kv、3150a、dt1-3150a、low voltage、heavy current、electrical、solidworks、step、flag terminal
- 数据更新
- 2026-11-19T19:28:47Z