EINSTEIN REFRIGERATOR  CYLE -TEST1 模型预览

GrabCAD 模型信息

EINSTEIN REFRIGERATOR CYLE -TEST1 · 模型 174662

作者:Freddo50

The cycle demonstrates a different approach to achieving absorption refrigeration without a solution pump. Compared to the Platen and Munters ammonia-water-hydrogen diffusion cycle, the processes appear to be less limited by gas diffusion, and the cycle offers the option for a wide selection of fluids to match a wider temperature range of applications. In addition, the Einstein cycle does not use hydrogen, which is relatively difficult to contain and is highly explosive. ammonia, water, and butane are not unique in absorption refrigeration applications (Taylor, 1929), the Einstein cycle’s configuration decouples the solution loops, and therefore allows for closer temperature matching. These issues and several options for improvement in the COP from the base case values of 0.15 to 0.20 are currently under study. The objective is to make this uniform pressure cycle without a solution pump competitive to ammonia-water two pressure cycles using solution pumps, which are problematic.