GrabCAD 模型信息
Far-UV Recessed 8" Square Light - (1) 10W Microplasma Board, 222 nm UVC Sanitation - Recessed Mount · 模型 197209
https://www.larsonelectronics.com/product/268738/far-uv-recessed-8-square-light-1-10w-microplasma-board-222-nm-uvc-sanitation-recessed-mount This unit is Made In USA - Manufactured in Texas The IND-CDL-SQ-8-FUVC-MP-1L-V1 from Larson Electronics is a Far-UV Recessed Square Light that disinfects 99% of viruses, bacteria, mold, and spores from ceilings in occupied areas. This eye and skin safe disinfection unit uses one 10-watt microplasma board that emits far-UV 222 nm germicidal light. Featuring an expected lifespan of 6,000+ hours, the unit is compatible with 120-277 V AC, 50/60 Hz. *Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual. UVC light in the proper setting kills up to 99.9% of viruses, mold, spores, and bacteria. Click here to learn more about UVC and the coronavirus* The IND-CDL-SQ-8-FUVC-MP-1L-V1 UV sanitation light is a powerful recessed lighting solution for buildings. This 10-watt unit consists of one microplasma board that provides 222nm far UV-C output. Equipped with an expected lifespan of 6,000+ hours, the light emits a flood beam pattern and is replaceable. This far-UV unit is capable of achieving up to 3 log (99.9%) cumulative disinfection per day. The sanitation light is offered with the following bezel finishes: black, white, brown, tan, chrome, brushed nickel, or brushed brass. Far-UV 222 nm light is considered to be eye and skin safe for humans, allowing the lamps to be used in occupied areas safely with minimum risk. The 222 nm wavelength does not penetrate the cornea of the eye and cannot impose corneal impairment. Additionally, this UV band is blocked by the top layer of skin (stratum corneum) which protects underlying cells from damage. Exposure to far-UV 222 nm lamp does not cause skin inflammation or swelling. Due to these safety benefits, extensive protective clothing is not required when using this type of sanitation light in occupied areas. Distance from Cart Irradiance/Second Exposure Time Required* Beam Width Beam Height 3 inch 417.73 uW/cm2 14.36 seconds 0.5 ft 0.5 ft 6 inch 236.35 uW/cm2 25.39 seconds 1 ft 1 ft 12 inch 118.73 uW/cm2 50.54 seconds 1.75 ft 1.75 ft 18 inch 65.96 uW/cm2 1.52 minutes 2.5 ft 2.5 ft 2 foot 872.35 uW/cm2 2.34 minutes 3 ft 3 ft 3 foot 456.77 uW/cm2 4.47 minutes 4.5 ft 4.5 ft 4 foot 230.26 uW/cm2 7.91 minutes 6 ft 6 ft 5 foot 147.36 uW/cm2 12.03 minutes 7.5 ft 7.5 ft 6 foot 102.34 uW/cm2 16.88 minutes 9 ft 9 ft 7...
- 格式
- Rendering、Other、STEP / IGES
- 分类
- Electrical、Fixtures、Industrial design
- 标签
- 未标注
- 数据更新
- 2026-09-21T04:48:38Z