The device is designed to monitor the insulation resistance of high-voltage circuits. A proprietary algorithm allows you to detect symmetrical and asymmetrical insulation faults between “plus” and “chassis”, “minus” and “chassis”. Communication is carried out via an isolated CAN 2.0B interface in accordance with the J1939 protocol or a specialized protocol. Supply voltage, V - 9…36 Digital interfaces - CAN 2.0B (J1939) High voltage line voltage range, V - 100…900 Maximum measured voltage, V - 1000 Insulation measurement range, MOhm - 3,5 Overall dimensions (LxWxH), mm - 100х51х20